Application

Internal splice connecting element for Beam Section TP F 80, particularly suitable for vertical extension. Should the component be used for horizontal application, the bending moment needs to be considered.

 

Installation

To be fastened with 2 x 4 FLS F Self Forming Screws. For optimal bending moment, distance between screws to be as far from each other as possible.

Notice:

Self Forming Screw FLS F to be fastened on two sides with a distance of minimum of 100mm and to be fastened symmetrically.

To optimise the bending moment the FLS F should be installed to maintain the pipe weight of the effective flow - i.e. screws are located top and bottom for horizontal cross bars not sideways.

 

Technical Data

TypeAdm. longitudinal 
force (tension/pressure) F
[kN]
Adm. bending 
moment Mb
[Nm]
PK F 80 4kt 10.0 500

Material: Steel, HCP.