Application

Universal use for anchorage of heavy loads even in areas with cracked concrete.Suitable for anchoring pipes, chennels, brackets and support plates in closed environments to the exclusion of damp environments.

 

     - No special drill required.

     - Simple and quick mounting.

     - Drive-in hammer zone for preventing any thread damage

 

Scope of delivery

Supplied with washer and hexagon nut.

 

Installation

1.   Drill bore hole according to the minimum bore hole depth

      perpendicularly to the surface.

2.   Remove dirt from hole.

3.   Drive the anchor into concrete up to its embedment mark.

4.   After tightening the anchor with a torque wrench Tinst (see torque indicated in the following tab),

       it may immediately  be submitted to loading.

 

Note the instructions in the mounting manual!

 

Technical Data

Standard anchoring depth:

TypeM8M10M12M16
Perm. load 1) tension C20/25 2) [kN] 2.4 4.3 7.6 11.9
C25/30 2) [kN] 2.6 4.7 8.3 13.1
C30/37 2) [kN] 2.9 5.2 9.3 14.5
C40/50 2) [kN] 3.4 6.0 10.8 16.8
C50/60 2) [kN] 3.7 6.6 11.8 18.5
Perm. load 1) oblique ≥ C20/25 2) [kN] 8.6
(5.0)3) 
12.6
(6.5)3) 
17.1
(8.5)3) 
26.9
(23.6)3)
Perm. bending moment 1) [Nm] 13.1 26.9
(25.7)3) 
46.9
(44.6)3) 
119.4
(99.,9)3)
Min. thickness of component hmin ≥ [mm] 100 120 140 170
( 3 hef ) Charact. centre distance scr [mm] 138 180 210 255
( 1.5 hef ) Charact. edge distance ccr [mm] 69 90 105 127.5
Min. centre distance s at/edge distance c ≥ [mm] 40/70 45/70 60/100 60/100
Min. edge distance c at/centre distance s ≥ [mm] 40/80 45/90 60/140 60/180
Effective anchoring depth hef [mm] 46
(35)3) 
60
(42)3) 
70
(50)3) 
85
(64)3)
Nominal diameter of drill d0 [mm] 8 10 12 16
Depth of bore hole h1 ≥ [mm] 60
(55)3) 
75
(65)3) 
90
(75)3) 
110
(95)3)
Anchoring torque Tinst [Nm] 20
(15)3) 
25
(30)3) 
45
(50)4) 
90
(100)3)
Perm. load 4) for fire exposure        
Perm. load R30 perm. F [kN] 1.3 2.2 3.2 6.0
Perm. load R60 perm. F [kN] 1.1 1.8 2.8 5.2
Perm. load R90 perm. F [kN] 0.8 1.4 2.4 4.4
Perm. load R120 perm. F [kN] 0.7 1.2 2.2 4.0

1) Loads for single anchors without influence of edge distances

2) Cracked concrete (option 1)

3) Edge/Centre distances in case of fire - respective approval is to be respected

 

Reduced anchoring depth:

Anchor size M8M10M12M16
Perm. load 1) tension C20/25 2) [kN] 2.4 3.6 6.1 9.0
C25/30 2) [kN] 2.6 3.9 6.6 9.8
C30/37 2) [kN] 2.9 4.3 7.4 10.9
C40/50 2) [kN] 3.4 5.1 8.6 12.7
C50/60 2) [kN] 3.7 5.5 9.4 13.9
Perm. load 1) oblique ≥ C20/25 2) [kN] 7.0 10.4 14.5 21.6
Perm. bending moment 1) [Nm] 13.1 26.9 46.9 123.4 
Min. thickness of component hmin ≥ [mm] 80 80 100 140
(3 hef ) Charact. centre distance scr [mm] 105 120 150 195
(1,5 hef ) Charact. edge distance ccr [mm] 52.5 60 75 97.5
Effective anchoring depth hef [mm] 35 40 50 65 
Nominal diameter of drill d0 [mm] 8 10 12 16
Depth of bore hole h1 ≥ [mm] 49 55 70 90 
Anchoring torque Tinst [Nm] 20 25 45 90 

1) Loads for single anchors without influence of edge distances

2) Cracked concrete (option 1)

TypeThread
connection
Standard
anchoring
depth
tfix
Reduced
anchoring
depth
tfix
Total length
[mm]
8/10/21/75 M8 10 21 75
8/30/41/95 M8 30 41 95
10/10/30/90 M10 10 30 90
10/20/40/100 M10 20 40 100
10/30/50/110 M10 30 50 110
10/50/70/130 M10 50 70 130
12/15/35/110 M12 15 35 110
12/30/50/125 M12 30 50 125
12/50/70/145 M12 50 70 145
16/25/45/145 M16 25 45 145
16/50/70/170 M16 50 70 170

 

Approvals

Approval ETA-10/0259

FM-approval for M10, M12, M16

VdS-conform for all sizes

Shock approval of the Federal Office for Civil Defence, Bern (Switzerland)

 