Welcome

Cart My cart 0 Items
Download PDF

Application

In combination with a channel, End Support WBD is particularly suitable for setting up structures attached to walls, floors and ceilings and in particular as a base for frame structures made of channels.

The generous dimensions and the rhomib shape of the mounting plate provide for a high bending moment and safely stabilise lateral loads.

 

Installation

Normally, two anchors grouped opposite to each other and along the load axis are sufficient. Only in exceptional cases (e.g. high props in frameworks) four anchors are required.

Tighening torque for hexagon bolts ≥ 40 Nm.

For ceiling mounting under high loads (up to 7.0 kN), we recommend the use of at least one fully traversing bolt for connecting the channel to the End Support WBD (for examples see "Installation Guidelines").

 

Technical Data

TypeSuitable for
channel
A
[mm]
s
[mm]
B
[mm]
b
[mm]
h
[mm]
C
[mm]
41/21-31 41/21/2.0 - 41/31/2.0 135 6 100 25 11 95
41/41-45 41/41/2.5 135 6 100 25 11 95
41/41-45 D 41/41/2.5 D 210 8 170 25 13 125

Working load for Wall mounting:

See tables on load charts for End Support WBD in chapter "Brackets"

The figures apply on walls if two anchors of the load class as stated are used.

 

Working load for Ceiling mounting:

The permissible maximum vertical load for ceiling mounting with Holding Bracket amounts to 2.0 kN. Using at least one traversing bolt (class 8.8) 7.0 kN.

 

Material:Steel, HCP.




 

= Sold by pack
Type
kg
Pack.
Avail.
Art.Cod.
Price
Q.ty