HEAVY ANCHOR INOX

Application

For universal use anchor heavy loads, even in areas of cracked concrete. Recommended for anchoring pipes, channels, brackets and support plates in closed environments to the exclusion of humid environments.

Features:

- No need for special equipment;

- Reduced drilling depth;

- Wide range of sizes, offering a safe and economical solution to every need;

- Ideal for fastening in tense areas of concrete structures subjected to shock

Blunt head for inserting percussion facilitated.

Pre-assembled nut and washer

 

Scope of delivery

Supplied with washer and hexagon nut.

 

Installation

1.   Drill bore hole according to the minimum bore hole depth

      perpendicularly to the surface.

2.   Remove dirt from hole.

3.   Drive the anchor into concrete up to its embedment mark.

4.   After tightening the anchor with a torque wrench Tinst (see torque indicated in the following tab),

       it may immediately  be submitted to loading.

 

Note the instructions in the mounting manual.

 

Technical Data

Material: stainless steel A4.

Anchor size M8M10M12M16
Perm. load 1) tension C20/25 2) [kN] 2.4 4.3 7.6 11.9
C25/30 2) [kN] 2.6 4.7 8.3 13.0
C30/37 2) [kN] 2.9 5.2 9.3 14.5
C40/50 2) [kN] 3.4 6.1 10.8 16.8
C50/60 2) [kN] 3.7 6.6 11.8 18.4
Perm. load 1) oplique C20/25 2) [kN] 7.4 11.4 17.1 31.4 
Perm. bending moment 1) [Nm] 14.9 29.7 52.6 114.3 
Min. thickness of component hmin ≥ [mm] 100 120 140 160
(3 hef ) Charact. centre distance scr [mm] 138 180 210 255
(1,5 hef ) Charact. edge distance ccr [mm] 69 90 105 127.5
Min. centre distance s at/edge distance c ≥ [mm] 40/70 50/75 60/100 60/100
Min. edge distance c at/centre distance s ≥ [mm] 40/80 55/90 60/140 60/180
Effective anchoring depth hef [mm] 46 60 70 85 
Nominal diameter of drill d0 [mm] 8 10 12 16 
Depth of bore hole h1 ≥ [mm] 60 75 90 110 
Anchoring torque Tinst [Nm] 20 35 50 110 
zul. Perm. load tenison 3) for fire exposure      
Perm. load R30 perm. F [kN] 1.3 2.3 4.0 6.3
Perm. load R60 perm. F [kN] 1.3 2.3 4.0 6.3
Perm. load R90 perm. F [kN] 1.3 2.3 4.0 6.3
Perm. load R120 perm. F [kN] 1.0 1.8 3.2 5.0

1) Loads for single anchors without influence of edge distances
2) Cracked concrete (option 1)
3) Consider edge and centre distances under fire exposure accord. to approval

TypeThread connectionStandard anchoring depth tfix [mm]Reduced
anchoring
depth
tfix
Total length [mm]
8/10/75 A4 M8 10 6 75
10/10/90 A4 M10 10 30 90
10/30/110 A4 M10 30 50 110
10/50/130 A4 M10 50 70 130
12/20/115 A4 M12 15 40 110
12/50/145 A4 M12 50 70 145
16/25/145 A4 M16 25 45 145
16/50/170 A4 M16 50 70 170

Approvals / Compliance

ETA Approval number: ETA-10/0259;

FM-Approval for M10, M12, M16 only for Standard anchoring depth;

VdS compliant for all sizes; 

Shock approval issued by the Federal Office for Civil Defence, Bern (Switzerland).

               logo_sprinkler.tif.33491.png        seismic_bearbeitet.tif.52835.png

HEAVY ANCHOR INOX
HEAVY ANCHOR INOX
Code Name Weight Number of pieces
114160 M 8/10/21/ 75 mm A4 0.03 100 Information request
114164 M10/10/30/ 90 mm A4 0.06 50 Information request
114166 M10/30/50/110 mm A4 0.07 50 Information request
114167 M10/50/70/130 mm A4 0.08 50 Information request
114168 M10/100/120/180 mm A4 0.08 50 Information request
114170 M12/20/40/115 mm A4 0.10 25 Information request
114172 M12/50/70/145 mm A4 0.13 25 Information request
114174 M16/25/45/145 mm A4 0.23 20 Information request
114175 M16/50/70/170 mm A4 0.27 20 Information request