DRIVE PLUG AN SS

Application

Hammerset Anchor for multiple attachment in cracked and single attachment in non-cracked concrete.

Suitable for fixing pipelines, channels, etc. meeting the respective approval requirements. To be used in structural parts under dry indoor conditions, as well as outdoor constructions (including industrial ambiance and coastal areas) or damp locations provided no special aggressive conditions are given.

     - No special drill is required

     - Setting Tool for Drive Plug is to be used as setting tool

       for distance-controlled forced expansion

     - Suitable for put-before assembly

 

Installation

As setting tool the respective expansion cone for drive plus is to be used.

The "intelligent" expansion cone facilitates the assembly with drill hole tolerances in the bore hole diameters or with different concrete.

Due to the controlled expansion the needed edge and centre distances are considerably reduced.

 

Technical Data

General installation data:

Anchor sizeM8x30M8x40M10M12
Perm. load for single anchor C20/25-C50/60 [kN] 1.7 2.0 2.0 2.4
Perm. bending moment (A4-70) Mperm [Nm] 11.9 11.9 23.8 42.1
Characteristical centre distance scr [mm] 180 210 170 200
Characteristical edge distance ccr [mm] 90 105 85 100
Loads under fire exposure        
Perm. load R30 perm. F [kN] 0.9 0.9 1.5 1.5
Perm. load R60 perm. F [kN] 0.9 0.9 1.5 1.5
Perm. load R90 perm. F [kN] 0.9 0.9 1.5 1.5
Perm. load R120 perm. F [kN] 0.4 0.4 1.0 1.2

 

Anchor sizeM8x30M8x40M10M12M16
Nominal dia. of drill d0 = [mm] 10 10 12 15 20
Depth of drill hole h0 = [mm] 30 40 40 50 65
Tightening torque when anchoring Tinst = [Nm] 8 8 15 35 60
Pass-through hole in component to be joined df ≤ [mm] 9 9 12 14 18
Thread length Lth [mm] 13 20 15 18 23
Minimum screw-in depth Lsdmin [mm] 9 9 11 13 18
Minimum thickness of component hmin [mm] 100 100 130 140 160
Min. centre distance smin [mm] 60 80 100 120 150
Min. edge distance cmin [mm] 95 95 135 165 200

 

Anchor sizeM8x30M8x40M10M12M16
Perm. tensile load C20/25 [kN] 3.3 3.6 6.1 8.5 12.6
Lateral tension perm. V ≥ C20/25 [kN] 4.6 4.6 6 11.9 19.2
Bending moments perm. M [Nm] 11.9 11.9 23.8 42.1 106.7


Material: Stainless steel A4 (316).

TypeDrill hole ø x 
depth [mm]
Thread ø x 
length [mm]
M8 x 30 10 x 30 M8 x 13
M8 x 40 10 x 40 M8 x 20
M10 x 40 12 x 40 M10 x 15
M12 x 50 15 x 50 M12 x 18
M16 x 65 20 x 65 M16 x 23

Approvals

For the multiple fixation of non-structural systems Approval ETA-10/0258 (M8-M12), for anchorage in non-cracked concrete Approval ETA-10/0257 (M8-M16), Fire Protection Certification, VdS-conform, FM-Approval ≥ M10.



                            

DRIVE PLUG AN SS
DRIVE PLUG AN SS
Code Name Weight Number of pieces
104906 M 8×30 mm A4 0.01 100 Information request
153593 M 8×40 mm A4 0.02 100 Information request
104915 M10×40 mm A4 0.02 50 Information request
104924 M12×50 mm A4 0.05 50 Information request
104933 M16×65 mm A4 0.11 25 Information request