DROP-IN ANCHOR AN ES

DROP-IN ANCHOR AN ES

Application

Drop-in Anchor for non-cracked concrete and multiple use in cracked concrete.

Suitable for fixing pipelines, channels, etc. meeting the respective approval requirements - for damp locations and outdoor constructions the stainless steel version is required.

 

     - No special drill required

     - Setting tool for distance-controlled forced expansion

     - Suitable for push-through mounting

 

Installation

As expansion tool use the respective expansion cone for Drop-In Anchor.

The "intelligent" expansion cone facilitates the mounting with bore dia. tolerances or varying concrete quality. By the controlled deformation of the cone during installation, the needed edge and centre distances are decreasing considerably.

 

Technical Data

General loads and performance data:


Anchor sizeM8x30M8x40M10x30M10x40M12M16
Nominal drill hole diameter d0 = [mm] 10 10 12 12 15 20
Depth of drill hole h0 = [mm] 30 40 30 40 50 65
Installation torque Tinst = [Nm] 8 8 15 15 35 60
Diameter of clearance hole in the connecting
element df ≤ [mm]
9 9 12 12 14 18
Maximun screwing depth Lth [mm] 13 20 12 15 18 23
Minimum screwing depth Lsdmin [mm] 9 9 10 11 13 18
Minimum thickness of concrete slab hmin [mm] 100 100 120 120 130 160
Minimum centre distance smin [mm] 60 80 100 100 120 150
Minimum edge distance cmin [mm] 95 95 135 135 165 200

Extract from Permissible Service Conditions of ETA-10/0258 cracked-concrete / Multiple use for nonstructural applications:

Anchor sizeM8x30M8x40M10x30M10x40M12M16
Approved loads for C20/25-C50/60 [kN] 1.7 2.0 2.0 2.0 2.4 6.3
Approved bending moments (Steel 4.6) Mperm [Nm] 6.4 6.4 12.8 12.8 22.2 56.9
Approved bending moments (Steel 8.8) Mperm [Nm] 17.1 17.1 34.3 34.3 60.0 152.0
Characteristic centre distance scr [mm] 180 210 230 170 170 400
Characteristic edge distance ccr [mm] 90 105 115 85 85 200
Loads under fire exposure Steel 4.6            
Approved loads R30 perm. F [kN] 0.4 0.4 0.9 0.9 1.5 3.1
Approved loads R60 perm. F [kN] 0.3 0.3 0.8 0.8 1.3 2.4
Approved loads R90 perm. F [kN] 0.3 0.3 0.6 0.6 1.1 2.0
Approved loads R120 perm. F [kN] 0.2 0.2 0.5 0.5 0.8 1.6
Loads under fire exposure Steel ≥ 5.6            
Approved loads R30 perm. F [kN] 0.9 0.9 1.5 1.5 1.5 4.0
Approved loads R60 perm. F [kN] 0.9 0.9 1.5 1.5 1.5 4.0
Approved loads R90 perm. F [kN] 0.9 0.9 1.5 1.5 1.5 3.7
Approved loads R120 perm. F [kN] 0.4 0.4 1.0 1.0 1.2 2.4

Extract from Permissible Service Conditions ETA-10/0257 non-cracked concrete:

Anchor sizeM8x30M8x40M10x30M10x40M12M16
Approved tensile load C20/25 (Stahl 4.6 to 8.8) [kN] 2.8 3.6 4.0 5.1 7.1 10.5
Oblique (Steel 4.6) perm. V ≥ C20/25 [kN] 3.1 3.1 3.7 4.1 7.2 13.4
Oblique (Steel 8.8) perm. V ≥ C20/25 [kN] 3.9 3.9 3.7 4.1 12.0 18.0
Bending moments (Screw 4.6) perm. M [Nm] 6.4 6.4 12.8 12.8 22.2 56.8
Bending moments (Screw 8.8) perm. M [Nm] 17.1 17.1 34.3 34.3 60.0 152.0

The values of the mentioned approvals in their latest version are valid

Material: Steel, electro-galvanised

 

Approvals

For multiple use for nonstructural applications Approval ETA-10/0258 (M8 - M12), for anchorage in non-cracked concrete Approval ETA-10/0257, Fire protection examination, VdS-conform, FM-Approval ≥ M10.

              logo_sprinkler.tif.33491.png


 

 

DROP-IN ANCHOR AN ES
DROP-IN ANCHOR AN ES
Code Name Weight Number of pieces
110467 AN ES M 8×30 0.01 100 Information request
110506 AN ES M10×30 0.02 50 Information request
110469 AN ES M10×40 0.02 50 Information request
110470 AN ES M12×50 0.04 50 Information request
110471 AN ES M16×65 0.10 - Information request